CompaRNA - on-line benchmarks of RNA structure prediction methods
Home

Methods
Datasets
Rankings
RNA 2D Atlas

Help
FAQ

Contact us
RSS feeds
Twitter

Table of contents:

  1. Overview

  2. Performance Plots

  3. Performance of RNASampler(seed) - scored higher in this pairwise comparison

  4. Performance of Multilign(20) - scored lower in this pairwise comparison

  5. Compile and download dataset for RNASampler(seed) & Multilign(20) [.zip] - may take several seconds...


Overview

Metric RNASampler(seed) Multilign(20)
MCC 0.450 > 0.378
Average MCC ± 95% Confidence Intervals 0.445 ± 0.310 > 0.377 ± 0.386
Sensitivity 0.331 = 0.331
Positive Predictive Value 0.615 > 0.437
Total TP 59 = 59
Total TN 37561 > 37522
Total FP 58 < 92
Total FP CONTRA 3 < 11
Total FP INCONS 34 < 65
Total FP COMP 21 > 16
Total FN 119 = 119
P-value 0.0

^top




Performance plots


  1. Comparison of performance of RNASampler(seed) and Multilign(20). Positive Predictive Value (PPV) is plotted against sensitivity. Each dot represents a single test of each method. See tables below for raw data (individual counts for RNASampler(seed) and Multilign(20)).

  2. Average Matthews Correlation Coefficients (MCC) with 95% confidence intervals (CIs) were plotted for different RNA families, for which at least 3 members were present in the benchmarking dataset. 'n' denotes the number of MCCs used to calculate the average and CI. See tables below for raw data (individual counts for RNASampler(seed) and Multilign(20)).

  3. Comparison of average Matthews Correlation Coefficients (MCCs) for RNASampler(seed) and Multilign(20). The whiskers correspond to 95% confidence intervals (CIs). 'n' denotes the number of MCCs used to calculate average MCCs and CIs. See tables below for raw data (individual counts for RNASampler(seed) and Multilign(20)).

^top





Performance of RNASampler(seed) - scored higher in this pairwise comparison

1. Total counts & total scores for RNASampler(seed)

Total Base Pair Counts
Total TP 59
Total TN 37561
Total FP 58
Total FP CONTRA 3
Total FP INCONS 34
Total FP COMP 21
Total FN 119
Total Scores
MCC 0.450
Average MCC ± 95% Confidence Intervals 0.445 ± 0.310
Sensitivity 0.331
Positive Predictive Value 0.615
Nr of predictions 5

^top



2. Individual counts for RNASampler(seed) [ download as .csv ]

RNA Chain Rfam family MCC SENS PPV TP TN FP FP CONTRA FP INCONS FP COMP FN
3J3E_8 0.12 0.09 0.17 3 7485 22 2 13 7 30
3J3F_8 0.44 0.33 0.57 12 12225 15 1 8 6 24
3RKF_A 0.76 0.59 1.00 20 2191 0 0 0 0 14
3SD1_A 0.60 0.38 0.94 16 3899 1 0 1 0 26
4A1C_2 0.31 0.24 0.40 8 11761 20 0 12 8 25

^top



Performance of Multilign(20) - scored lower in this pairwise comparison

1. Total counts & total scores for Multilign(20)

Total Base Pair Counts
Total TP 59
Total TN 37522
Total FP 92
Total FP CONTRA 11
Total FP INCONS 65
Total FP COMP 16
Total FN 119
Total Scores
MCC 0.378
Average MCC ± 95% Confidence Intervals 0.377 ± 0.386
Sensitivity 0.331
Positive Predictive Value 0.437
Nr of predictions 5

^top



2. Individual counts for Multilign(20) [ download as .csv ]

RNA Chain Rfam family MCC SENS PPV TP TN FP FP CONTRA FP INCONS FP COMP FN
3J3E_8 0.00 0.00 0.00 0 7481 22 6 16 0 33
3J3F_8 0.41 0.36 0.46 13 12218 27 1 14 12 23
3RKF_A 0.77 0.62 0.95 21 2189 1 0 1 0 13
3SD1_A 0.57 0.48 0.69 20 3887 9 1 8 0 22
4A1C_2 0.15 0.15 0.15 5 11747 33 3 26 4 28

^top


Matthews Correlation Coeffient, Sensitivity and Positive Predictive Value have been calculated based on the paper by Gardener & Giegerich, 2004.